Home / Sprinklers / Rain Bird

Sprinklers & irrigation

How do I winterize a Rain Bird sprinkler system?

Direct answer

Rain Bird’s own guidance comes down to four jobs: shut off and insulate the irrigation water supply, turn the controller to OFF (or rain mode) and leave it powered unless it runs a pump, get the water out of the pipes, valves, and heads (manual drain valves, 16A-FDV automatic drains, or a compressed-air blowout at no more than 50 psi), then protect valves and backflow preventers without blocking their vents and drains. On Rain Bird’s controllers, that means the OFF dial position on an ESP-TM2 or ESP-Me3, or OFF status on an ST8. Seasonal Adjust and Delay Watering are not winter shutoffs. Rain Bird recommends an irrigation specialist if you are unsure about any of it.

What you’ll need

  • Eye protection
  • Access to the irrigation main shutoff valve and your Rain Bird controller (and its manual, or the model number so you can look it up)
  • Access to every manual drain valve or drain cap on the mainline, if the system has them
  • Foam insulation tape or foam pipe tubes, plus a plastic bag for wrapping the main shutoff (Rain Bird’s suggestion)
  • For a blowout only: a compressor with a pressure regulator and a blowout adapter on the mainline. The full procedure is in our sprinkler blowout guide.

Steps

  1. Shut off and insulate the irrigation water supply. Rain Bird says to close the main shutoff for the irrigation system and wrap it in foam insulation tape and a plastic bag so it cannot freeze. Rain Bird also suggests installing one if you do not have a main shutoff. Insulate any above-ground piping with self-sticking foam tape or foam tubes.
  2. Decide how you will drain the system before touching the controller. Rain Bird lists three methods: manual drain valves, automatic drain valves, or a compressed-air blowout. If you are blowing out the lines, leave the controller working for now. Rain Bird’s blowout procedure has you advance zones from the timer and turn it to OFF only at the end.
  3. Manual drain valves: relieve pressure first. Rain Bird’s steps: (1) turn off the mainline shutoff, (2) open one zone control valve by hand or from the timer to relieve mainline pressure, (3) slowly open the manual drain valve, and (4) repeat for every manual drain on the mainline. Rain Bird says manual drains belong at the lowest point of the mainline (plus any additional low points). A ball valve, gate valve, stop-and-waste valve, or capped threaded pipe can serve as the drain.
  4. Automatic drain valves: check for puddles. Rain Bird’s 16A-FDV automatic drain is a spring-loaded valve that opens every time the system shuts off. It drains the lateral pipes between the zone valves and the heads, so you should not need to open it by hand. Look for heavy puddling on the soil, which can mean a drain is stuck open. Rain Bird says not to install automatic drains on the mainline, so the mainline still needs a manual drain or a blowout.
  5. Blowout: follow Rain Bird’s limits. Rain Bird’s guide caps air pressure at 50 psi, recommends a compressor that delivers 10 to 25 CFM, and limits each zone to 2 minutes at a time. Open the zone farthest from the air connection before introducing air, run two or more cycles per zone until only a fine mist appears, leave one zone on while you shut down the compressor, and then turn the timer to OFF. The complete step-by-step procedure, including pipe-type limits from other manufacturers, is in our blowout guide.
  6. Deal with water left in the valves. Rain Bird says gravity draining will not remove water trapped inside the zone valves, and turning them on by hand or from the timer is not an effective way to drain them. If you did not blow out the system, Rain Bird’s guide says diaphragm-style valves (it lists DAS, CP, CPF, and EV-100 models) should be taken apart: remove the bonnet, solenoid, and diaphragm, drain or sponge out the water, reassemble, and leave the solenoid in the open position. Valves that were blown out do not need to be taken apart. Rain Bird says to leave them in the manual open position (bleed screw or solenoid turned counterclockwise) so they cannot repressurize over the winter.
  7. Check sprinkler heads with special inlets or check valves. Rain Bird notes that if a head is plumbed through its side inlet, a drain valve should be fitted on the bottom inlet so the case does not freeze. Heads with built-in check valves (mostly commercial installations, according to Rain Bird) must be taken apart or blown out with air.
  8. Put the controller in winter mode. With no pump, Rain Bird’s guide says to turn a dial or switch timer to OFF (or RAIN or RAIN/OFF where it exists) and leave it plugged in. The program stays in memory, and the warmth helps ward off condensation. On an ESP-TM2 or ESP-Me3, turn the dial to OFF. Both manuals say watering will not occur while the controller stays in OFF. On an ST8 WiFi timer, Rain Bird’s support article describes an OFF status at the controller, which you clear in spring by pressing Auto. If your timer runs a pump, follow the pump steps in the FAQ below instead.
  9. Protect the backflow preventer. Rain Bird says to check with the backflow manufacturer for its specific steps. After draining, leave the shutoff valves open, with ball-type shutoffs at a 45-degree angle. Insulate the device or use heat tape in extreme conditions, but do not block its air vents or drain outlets. Colorado State University Extension adds that pressure vacuum breakers (PVBs) and reduced-pressure (RP) devices must never be blown out with compressed air because the rubber seals can melt.
  10. Insulate above-ground valves with insulation tape, as Rain Bird suggests. Leave the water off until spring.

Common mistakes and variations

Using Seasonal Adjust or Rain Delay instead of OFF

Seasonal Adjust on the ESP-TM2 and ESP-Me3 only scales run times between 5% and 200%. Delay Watering suspends watering for up to 14 days, and the ESP-TM2 manual says automatic irrigation resumes as scheduled when the delay ends. Rain Bird’s ST8 support article describes Rain Delay as a day countdown that can be set at the timer or in the Rain Bird app. None of these is a winter shutoff.

Forgetting about the app or a remote

The ESP-Me3 manual notes that manual watering can still be started from mobile apps or a LIMR remote while the dial is in OFF. If other people or a landscaper share access to the controller, tell them the system is winterized. Rain Bird’s ST8 support article also notes that a Rain Delay can be set either at the controller or through the app.

Systems with a pump

Rain Bird’s winterizing page tells owners of pump systems to remove the wires on the MV and common terminals so the pump cannot start by accident and overheat. Its Homeowner’s Guide says a keypad OFF or a mechanical switch does not guarantee the timer stays off after a power surge or outage. For indoor timers, it says to unplug the transformer, which may be hot (use gloves), and remove the backup battery. Doing that erases the program on digital models. Rain Bird also says to check the pump manufacturer’s own winterization instructions.

Trusting gravity drains completely

Rain Bird presents manual and automatic drains as valid methods for a system designed for them. Colorado State University Extension (fact sheet reviewed August 2025) disagrees: it says not to trust manual or automatic drain valves alone and to use compressed air, because buried pipe shifts over time. If you rely on drains, see our guide to winterizing without a blowout for the limits of that approach.

Controller exercise cycles

Colorado State University Extension also says the controller should stay powered all winter and suggests programming a short weekly cycle to keep solenoid plungers from sticking. Rain Bird’s guide says to turn the timer to OFF. If you are unsure which to follow for your setup, ask your installer.

FAQ

Should I turn my Rain Bird timer to OFF or unplug it for winter?

For a system without a pump, Rain Bird’s Homeowner’s Guide to Winterization says to turn a dial or switch timer to OFF (or RAIN or RAIN/OFF on models that have it) and leave it plugged in, because the program stays intact and the unit’s warmth helps ward off condensation. Rain Bird’s winterizing page notes that if you shut off power instead, you may need to reprogram the time and other settings in spring. Systems with a pump are different: see the pump question below.

Does Seasonal Adjust or Delay Watering winterize the controller?

No. In the ESP-TM2 and ESP-Me3 manuals, Seasonal Adjust only scales run times from 5% to 200% (at 50%, a 10-minute run becomes 5 minutes). Delay Watering suspends watering for up to 14 days, and the ESP-TM2 manual notes that automatic irrigation resumes as scheduled when the delay expires. Rain Bird’s ST8 support article likewise describes Rain Delay as a countdown in days. Use the OFF position for the winter.

My Rain Bird controller runs a pump. What is different?

Rain Bird’s winterizing page says that if the controller activates a pump, you should remove the wires connected to the MV (master valve) and common terminals as a precaution so the pump cannot be switched on accidentally and overheat. The Homeowner’s Guide explains that turning a timer off from the keypad does not guarantee it will stay off after a power surge or failure. For hard-wired outdoor timers it says to turn power off at the breaker first and warns never to disconnect the high-voltage wires yourself; call Rain Bird or an irrigation contractor if you are unsure.

If I have Rain Bird automatic drain valves, do I still need a blowout?

Rain Bird’s guide says 16A-FDV automatic drains belong on lateral lines after the zone valves, not on the mainline, so the mainline still needs a manual drain or a blowout. It also says gravity draining will not remove water trapped inside the valves: diaphragm valves that are not blown out with air should be taken apart and drained. Colorado State University Extension goes further and recommends a compressed-air blowout because buried pipe can shift and trap water.

What air pressure does Rain Bird recommend for a blowout?

Rain Bird’s Homeowner’s Guide to Winterization says air pressure must not exceed 50 psi and tells you to set the compressor’s regulator to 50 psi. It recommends a compressor that can deliver 10 to 25 CFM and warns against using a high-pressure (120 psi), low-volume compressor. Rain Bird’s 2025 blog post repeats the 50 psi regulator setting in its step-by-step procedure.

Sources

We checked these pages and documents while writing this guide. Follow your own manual if it differs.

  1. How Do I “Winterize” My Irrigation System? — Rain BirdRain Bird’s four-step homeowner overview: insulate the shutoff, put the controller in rain mode (or remove MV/common wires for pumps), drain the pipes, and insulate backflow preventers without blocking vents or drains.
  2. Homeowner’s Guide to Winterization (PDF) — Rain BirdManual drain and 16A-FDV automatic drain design and procedures, 50 psi blowout limit and 10–25 CFM compressor guidance, valve and sprinkler-head notes, timer methods with and without pumps, and backflow ball valves at 45 degrees.
  3. Fall is Blow-Out Season: Tips for Winterizing Your Sprinkler System — Rain BirdOctober 20, 2025 Rain Bird article: manual and automatic drain procedures, 50 psi regulator setting, 2-minute cycle limit, and gear-drive rotor overheating warning.
  4. ESP-TM2 Controller User Manual (PDF) — Rain BirdOFF dial position, Seasonal Adjust (5%–200%), Delay Watering up to 14 days, and rain sensor ACTIVE/BYPASS settings.
  5. ESP-ME3 Controller User Manual (PDF) — Rain BirdOFF dial position, the note that manual watering can still start from mobile apps or LIMR while in OFF, Seasonal Adjust, and Delay Watering.
  6. ST8 Not Running – Stop/OFF Icon on the Screen — Rain Bird Connected Device SupportST8-WiFi and ST8-2.0 OFF status and Auto button, and Rain Delay set at the controller or in the Rain Bird app.
  7. Home Sprinkler Systems: Preparing Your Sprinkler System for Winter — Colorado State University ExtensionFact sheet 4.719 (reviewed August 2025): never blow air through PVB or RP backflow devices, draining a PVB, caution about gravity drains, and keeping the controller powered.

Related guides